Optical cables for vertical wiring in buildings, which is a major component of the dropsegment in FTTx networks, refer to the drop cables going from ducts in buildings intorooms. Vertical wiring is mainly applied to high-storey buildings, super high-storeybuildings, buildings with high-density subscribers and large information processing centers such as data centers.
Characteristics
| Availability: | |
|---|---|
GJJA
Optical Characteristics
| G.657.B3 | ||
| Attenuation | @1310nm | ≤0.36 dB/km |
| @1550nm | ≤0.25 dB/km |
Technical Data
| Item | Contents | Value |
| Fibre Count | 1 | |
| Tight buffer fiber | material | PA12 |
| diameter(mm) | 0.90±0.05mm | |
| Cable weight(kg/km)Approx | 0.7 | |
| Operating temperature range(℃) | -40~+70 | |
| Tensile Strength Short/Long Term(N) | 6/3 | |
| Crush resistance short/long term (N/100mm) | 500/100 | |
Main Mechanical and Environmental Performances
| Item | Test Standard | Specified Value | Requirements |
| Tension | IEC 60794-1-2-E1 | See Technical data | Additional attenuation ≤ 0.4dB after test |
| Crush | IEC 60794-1-2-E3 | See Technical data | Additional attenuation ≤ 0.4dB after test |
| Impact | IEC 60794-1-2-E4 | R=300mm, 10Nm one in 3 different places | Additional attenuation ≤ 0.4dB after test |
| Repeated Bending | IEC 60794-1-2-E6 | R=20*D | Additional attenuation ≤ 0.4dB after test |
| Temperature Cycling | IEC 60794-1-2-F1 | -20°C~+70°C | Attenuation change: ≤ 0.4dB/km after test |
All optical measurements at 1550nm.
Packing and Reel Length
Standard reel length: 1/2km/reel.